Measured Data
Thermal Conductivity
Experiments for thermal conductivity [W/(m K)] were conducted using a heat flow meter on unconditioned and dried samples at 15 °C and either 45 °C or 65 °C.
Unconditioned
| Temperature (C) | Conductivity Mean (W/m-K) | Standard Deviation (W/m-K) |
|---|---|---|
| 15.0 | 0.053 | 0.0 |
| 65.0 | 0.064 | 0.0 |
Derived Data
Band Averaged Emissivity
Band averaged emissivity was calculated from reflectance measurements conducted with an integrating sphere and Fourier transform infrared spectrometer.
| Source Temperature [K] | Emissivity | Std. Dev. |
|---|---|---|
| 600.0 | 0.925 | 0.002 |
| 800.0 | 0.900 | 0.003 |
| 1000.0 | 0.866 | 0.005 |
| 1200.0 | 0.828 | 0.008 |
| 1400.0 | 0.791 | 0.011 |
| 1600.0 | 0.759 | 0.014 |
| 1800.0 | 0.733 | 0.018 |
| 2000.0 | 0.711 | 0.020 |