Measured Data

Expand all

Thermal Conductivity

Experiments for thermal conductivity [W/(m K)] were conducted using a heat flow meter on unconditioned and dried samples at 15 °C and either 45 °C or 65 °C.

Expand all

Unconditioned

20304050600.0540.0560.0580.060.0620.064
Temperature (°C)Thermal Conductivity (W/mK)Repository Version: d492829
Temperature (C) Conductivity Mean (W/m-K) Standard Deviation (W/m-K)
15.0 0.053 0.0
65.0 0.064 0.0

Derived Data

Expand all

Band Averaged Emissivity

Band averaged emissivity was calculated from reflectance measurements conducted with an integrating sphere and Fourier transform infrared spectrometer.

6008001000120014001600180020000.70.750.80.850.9
Source Temperature [K]Total Hemispherical EmissivityRepository Version: d492829
Source Temperature [K] Emissivity Std. Dev.
600.0 0.925 0.002
800.0 0.900 0.003
1000.0 0.866 0.005
1200.0 0.828 0.008
1400.0 0.791 0.011
1600.0 0.759 0.014
1800.0 0.733 0.018
2000.0 0.711 0.020