Measured Data

Mass Loss Rate (MLR)

Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min.

Simultaneous Thermal Analyzer

Derived Data

Temperature at Onset of Decomposition

The temperature at onset of decomposition [Tonset] is a derived quantity computed from data collected in simultaneous thermal analyzer experiments.

10 °C/min 30 °C/min
Mean Onset Temperature (°C) 443 467
Std. Dev. Onset Temperature (°C) 5 7
Mean Normalized MLR at Onset (1/s) 9.73e-04 1.05e-03
Std. Dev. Normalized MLR at Onset (1/s) 0.97e-04 0.06e-03
Mean Mass Fraction at Onset 0.98 0.98
Std. Dev. Mass Fraction at Onset 0.00 0.00
Mean Temperature at end of Decomposition (°C) 541 574
Std. Dev. Temperature at end of Decomposition (°C) 10 14