Measured Data

Mass Loss Rate (MLR)

Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min.

Simultaneous Thermal Analyzer

Derived Data

Temperature at Onset of Decomposition

The temperature at onset of decomposition [Tonset] is a derived quantity computed from data collected in simultaneous thermal analyzer experiments.

10 °C/min 30 °C/min
Mean Onset Temperature (°C) 141 128
Std. Dev. Onset Temperature (°C) NaN NaN
Mean Normalized MLR at Onset (1/s) 1.79e-04 1.80e-04
Std. Dev. Normalized MLR at Onset (1/s) NaN NaN
Mean Mass Fraction at Onset 0.96 0.97
Std. Dev. Mass Fraction at Onset NaN NaN
Mean Temperature at end of Decomposition (°C) 605 540
Std. Dev. Temperature at end of Decomposition (°C) NaN NaN