Measured Data

Mass Loss Rate (MLR)

Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min.

Simultaneous Thermal Analyzer

Derived Data

Temperature at Onset of Decomposition

The temperature at onset of decomposition [Tonset] is a derived quantity computed from data collected in simultaneous thermal analyzer experiments.

10 °C/min
Mean Onset Temperature (°C) 208
Std. Dev. Onset Temperature (°C) NaN
Mean Normalized MLR at Onset (1/s) 2.53e-04
Std. Dev. Normalized MLR at Onset (1/s) NaN
Mean Mass Fraction at Onset 0.99
Std. Dev. Mass Fraction at Onset NaN
Mean Temperature at end of Decomposition (°C) 636
Std. Dev. Temperature at end of Decomposition (°C) NaN