Measured Data
Mass Loss Rate (MLR)
Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min.
Simultaneous Thermal Analyzer
Derived Data
Temperature at Onset of Decomposition
The temperature at onset of decomposition [Tonset] is a derived quantity computed from data collected in simultaneous thermal analyzer experiments.
| 10 °C/min | 30 °C/min | |
|---|---|---|
| Mean Onset Temperature (°C) | 233 | 256 |
| Std. Dev. Onset Temperature (°C) | 3 | NaN |
| Mean Normalized MLR at Onset (1/s) | 6.83e-04 | 6.43e-04 |
| Std. Dev. Normalized MLR at Onset (1/s) | 0.99e-04 | NaN |
| Mean Mass Fraction at Onset | 0.98 | 0.98 |
| Std. Dev. Mass Fraction at Onset | 0.00 | NaN |
| Mean Temperature at end of Decomposition (°C) | 492 | 509 |
| Std. Dev. Temperature at end of Decomposition (°C) | 0 | NaN |