Measured Data
Mass Loss Rate (MLR)
Initial-mass-normalized mass loss rate [1/s] was measured in the simultaneous thermal analyzer experiments at three heating rates: 3 K/min, 10 K/min, and 30 K/min.
Simultaneous Thermal Analyzer
Derived Data
Temperature at Onset of Decomposition
The temperature at onset of decomposition [Tonset] is a derived quantity computed from data collected in simultaneous thermal analyzer experiments.
| 10 °C/min | 30 °C/min | |
|---|---|---|
| Mean Onset Temperature (°C) | 173 | 219 |
| Std. Dev. Onset Temperature (°C) | 15 | 10 |
| Mean Normalized MLR at Onset (1/s) | 1.52e-04 | 1.67e-04 |
| Std. Dev. Normalized MLR at Onset (1/s) | 0.16e-04 | 0.42e-04 |
| Mean Mass Fraction at Onset | 0.99 | 0.99 |
| Std. Dev. Mass Fraction at Onset | 0.00 | 0.00 |
| Mean Temperature at end of Decomposition (°C) | 539 | 539 |
| Std. Dev. Temperature at end of Decomposition (°C) | 45 | 21 |